-------------------------------------------------------------------------------- -- Copyright © 2011 National Institute of Aerospace / Galois, Inc. -------------------------------------------------------------------------------- -- | Example implementing an engine cooling control system. {-# LANGUAGE RebindableSyntax #-} module Main where import Language.Copilot import qualified Prelude as P {- If the majority of the engine temperature probes exeeds 250 degrees, then - the cooler is engaged and remains engaged until the majority of the engine - temperature probes drop to 250 or below. Otherwise, trigger an immediate - shutdown of the engine. -} engineMonitor :: Spec engineMonitor = do trigger "shutoff" (not ok) [arg maj] where vals = [ externW8 "tmp_probe_0" two51 , externW8 "tmp_probe_1" two51 , externW8 "tmp_probe_2" zero] exceed = map (> 250) vals maj = majority exceed checkMaj = aMajority exceed maj ok = alwaysBeen ((maj && checkMaj) ==> extern "cooler" cooler) two51 = Just $ [251, 251] P.++ repeat (250 :: Word8) zero = Just $ repeat (0 :: Word8) cooler = Just $ [True, True] P.++ repeat False main :: IO () main = interpret 10 engineMonitor